Gck Model Metal-Clad Low Voltage Withdrawable Switchgear

Model NO.: Low Voltage Withdrawable Switchgear
Outing Structure: Metal-Enclosed Structure or Metal Clad
Components: Switches, Circuit Breakers, Fuses, Arrestors
Functions: Protection, Isolation, Electricity Distribution
Warranty Period: One Year
Product Type: OEM or ODM Customized Switchgear Products
Cabinet Parts: Incoming, Outing, Metering, Compensating
Protective Level: IP Level Value According The Applied Environment
Certification 01: GB/T 19001-2008/ISO9001:2008
Certification 02: GB/T 28001-2011/Ohsas18001:2007
Certification 03: GB/T 24001-2004/ISO14001:2004
Trademark: SHENRONG ELECTRIC
Transport Package: Normal Exporting Package
Specification: GCK Model Low Voltage Withdrawable Switchgear
Origin: China
HS Code: 8537109090
1. Product Name:
  Gck Model Metal-Clad Low Voltage Withdrawable Switchgear

2. Product Description:

     Rongdian produce GCK(L)model alternative current low voltage withdrawable switchgear cabinet, which is combined low voltage full set switchgear equipment of international advanced level. It is made up of power distribution center (PC) and motor control center(MMC) two parts and is used in alternative current frequency 50HZ and three phase distribution electricity system of rated work voltage 660V and below. Also it can be used of power electricity receiving, power electricity infeed, illumination, electronic motor control and reactive power compensation for power station, transformer substation, industrial and mining enterprises and high altitude building. 

3. Model explanation:

    Gck Model Metal-Clad Low Voltage Withdrawable Switchgear

4. Performance Features:

    (1) The main framwork adopt C type steel, standard modularization design. Modulus is 25mm and parts have strong popularity, flexible and convenient installation inside. 
    (2) When the cabinet is designed, the thermal issue is taken into consideration fully. Up and down of cabinet body has designed different quantities scattered heat slot holes, which make the sealed cabinet to form a nature ventilation from bottom to top and it can achieve heat scattered purpose.
    (3) Each functional chamber of device is isolated from each other and the interval room is divided into function unit room, bus line room and cable room, relative independent of each chamber function. 
    (4) The head cover of cabinet can be uninstalled when required, which make the main bus line more convenient assembly and adjustment in scene. There are flying rings installed in the four corners of cabinet head cover, which is used for slinging and loading. 
    (5) It has locking function, self-throwing function and checking status function.
    (6) It can support various operating patterns(selectable);
    (7) Having communication function: the system can have SR485 or RS232 communicating interface, which can support MODBUS cpmmunication regulation(selectable);
    (8) It has intelligentized monitoring function(selectable);

5. Technology parameters:
Technology Parameters    
Item Unit Parameters
Rated Working Voltage V 400
Rated Frequency Hz 50/60
Rated Current Horizontal bus line A ≤4000
Vertical bus line A ≤1000
Rated short-time tolerant current(1s) kA 50
Rated peak tolerant current kA 105
Dielectric Strength V/1min 2500
Rated Insulation Voltage V 660
Effective installed height mm 1800
Drawer Specification 400mm Height(16E) mm 250A≤In≤630A
200mm Height(8E) mm 63A≤In≤250A
200/2mm Height(8E/2) mm In≤63A
Control Motor Capacity kW 300
Out shell protection level   IP30/IP40
Shape dimension(Width×Length×Thickness) MM (600-1000)×1000×2200

6. Pictures as below: 
Gck Model Metal-Clad Low Voltage Withdrawable Switchgear


Gck Model Metal-Clad Low Voltage Withdrawable Switchgear
Gck Model Metal-Clad Low Voltage Withdrawable Switchgear
Gck Model Metal-Clad Low Voltage Withdrawable Switchgear
Gck Model Metal-Clad Low Voltage Withdrawable Switchgear

7. Ordering Instructions
Ordering instruction(Armored Movable Alternative Current Metal Sealed Switchgear Equipment)
Please provide those below detailed information, when you order the switchgear.
001 Main connection wire solution serial number and single line system diagram, arrangement and plane layout drawing
002 Main connection line solution serial number, purpose and single line system diagram, rated voltage, rated current, rated short circuit breaking current, distribution electricity chamber plane layout diagram, arrangement diagram of switchgear and so on. 
003 Secondary connection wire diagram, terminals arrangement diagram. If you can't provide terminals arrangement diagram, we will provide the terminals arrangement according to manufacturer's diagram.
004 Requirement of switchgear control,measurement and protection function and requirement of other shutting and automatic device.
005 Model, specificaton, quantity of switchgear equipment's electrical apparatus elements
006 Electrical equipments summary sheet
007 If the interspace of switchgears or incoming line cabinet need bus line bridge to connect, please provide rated load current of bus line bridge. 
008 If you need busbar (busbar between two array cabinets and busbar between wall cabinets), please provide detailed span and high altitude distance.
009 If the switch equipments are used in the special environment conditions, please put forward it when you order the switchgear.
010 When you need other apparatus or exceed attachment supplied equipment list, please put forward model and quantity you need.
011 Other special requirements.

8. FAQ
001 Q What is electrical switchgear
A Electrical switchgear is a key component in electrical power systems and is used to both distribute electrical power and to selectively isolate electrical loads.
The switchgear is a switching device comprising of connecting or disconnecting switches, fuses or circuit breakers, protective and controlling devices which can be used to isolate electrical apparatus in faulty condition or during maintenance period, or to connect the same in desired healthy conditions.
002 Q Do we need to monitor the switchgear conditions
A Yes, Because switchgear distributes electrical current, heat build-up becomes an important characteristic to monitor. In particular, unexpected temperature rise at a particular location could indicate corrosion or some other type of defect. Thermal effects are especially visible in medium voltage switch gears used in distribution networks, where electrical currents may rise to few thousands of amperes. Thus keeping switchgears in proper condition over their long life becomes a critical issue.
003 Q What are the main causes of arc flashes in industrial switchgear?
A The main causes of arc flashes in industrial switchgear are: the application of tools to energize switchgear, deteriorated insulation on phase bus bars, and loose 
electrical connections that overheat. These things can be prevented by proper safety measures and regular maintenance.
004 Q What is the lowest voltage at which arc flashes occur?
A 120 volts is generally considered the lowest voltage at which arc flashes occur. The voltage of industrial switchgear can exceed this voltage by hundreds of thousands of 
times.
005 Q What is Metal Enclosed Switchgear?
A Metal Enclosed Switchgear is a switchgear assembly that encloses all necessary equipment and device in separate metal vertical structure (i.e MCCs, PCC), however they 
each metal compartment are not separated from one another by metal barriers. It's used often with low voltage equipment. 
006 Q What is Metal Clad switchgear?
A Metal Clad Switchgear is a switchgear assembly that encloses all necessary equipment and devices in one metal house, but compartments in this assembly is separated from
one another by metal barrier. When metal clad switchgear is used or assumed when MV switchgear is provided.
007 Q Difference between Metal Enclosed Switchgear and metal Clad Switchgear.
A Metal enclosed switchgear: Assembled with separate metal vertical section
Metal Clad Switchgear: Assembled in one metal structure.
MES: each compartment is not separated from one another with metal barrier.
MCS: each compartment is separated from one another with metal barrier.
MES: Frequently used in LV system.
MCS: Frequently used in MV System. When MCS is said MV Switchgear is assumed.
MES: All breakers and other switching devices are fixed type.
MCS: All breakers are withdrawable type.

APM offers 3 Phase Ac Power Source system. It`s single 3-phase output Programmable Ac Power Supply which provides with high power density. With high speed DSP+CPLD control, high frequency PWM technology, active PFC design, It is able to provide not only stable DC/AC output power,but also 3-phase / 1-phase output.

The 3 Phase Ac Power Supply is featured with high power density, high reliability and high precision, meanwhile it possesses operation interface of touch screen and keys manually. It is able to analog output normal or abnormal power input for electrical device to meet test requirements, which is applicable to electric, lighting, aviation sectors, etc. It could be applied to enterprise`s production test as well.

Some features as below:


  • 5.6" large touch color screen, possess complete functions and easy to operate.
  • Support for USB data import/export and screen snap from front panel.
  • AC+DC mixed or independent output mode for voltage DC offset simulation.
  • Capable of setting voltage and current output restriction, support for constant current output mode.
  • Capable of setting output slope of voltage and frequency.
  • Capable of setting ON/OFF phase angle.
  • With reverse current protection to avoid current flowing backward.
  • Built-in power meter, which is capable of measuring 5 electrical parameters per phase, including voltage, current, power, etc.
  • Support mA current measurement function.


Three Phase AC Source System

Three Phase Ac Source System,Programmable 3 Phase Ac Power Supply,Ac Source System,Three Phase Source

APM Technologies (Dongguan) Co., Ltd , http://www.apmpowersupply.com